RevPi Connect+/Connect
RevPi Connect+
Processor: Broadcom BCM2837B0
Number of cores: 4
Clock rate: 1.2 GHz
RAM: 1 GB
eMMC flash memory: 8-32 GB
RevPi Connect
Processor: Broadcom BCM2837
Number of cores: 4
Clock rate: 1.2 GHz
RAM: 1 GB
eMMC flash memory: 4 GB
RevPi Core 3+/Core 3/Core
RevPi Core 3+
Processor: Broadcom BCM2837B0
Number of cores: 4
Clock rate: 1.2 GHz
RAM: 1 GB
eMMC flash memory: 8-32 GB
RevPi Core 3
Processor: Broadcom BCM2837
Number of cores: 4
Clock rate: 1.2 GHz
RAM: 1 GB
eMMC flash memory: 4 GB
RevPi Core 3
Processor: Broadcom BCM2837
Number of cores: 4
Clock rate: 1.2 GHz
RAM: 1 GB
eMMC flash memory: 4 GB
Digital IO modules
RevPi DIO
Standard version RevPi DIO has 14 digital inputs and 14 digital outputs
RevPi DI
Special version RevPi DI has 16 digital inputs but no outputs
RevPi DO
Special version RevPi DI has 16 digital outputs but no inputs
Analog IO modules
RevPi AIO Analog IO module
CON expansion modules
RevPi Con M-Bus: Wireless M-Bus module (868 MHz)
RevPi Con M-Bus VHP: Wireless M-Bus module (169 MHz)
RevPi Con CAN: CAN bus module
Gateway modules
Protocol PROFINET IRT
Master/Slave: Slave
Bus connector: 2 x RJ45
Max. baud rate: 100 Mbit/s
I/O Data: 512 Bytes IN/OUT
Protocol EtherNet/IP
Master/Slave: Slave
Bus connector: 2 x RJ45
Max. baud rate: 100 Mbit/s
I/O Data: 480 Bytes IN/OUT
Protocol POWERLINK
Master/Slave: Slave
Bus connector: 2 x RJ45
Max. baud rate: 100 Mbit/s
I/O Data: 512 Bytes IN/OUT
Protocol EtherCAT
Master/Slave: Slave
Bus connector: 2 x RJ45
Max. baud rate: 100 Mbit/s
I/O Data: 512 Bytes IN/OUT
Protocol Sercos III
Master/Slave: Slave
Bus connector: 2 x RJ45
Max. baud rate: 100 Mbit/s
I/O Data: 512 Bytes IN/OUT
Protocol Modbus TCP
Master/Slave: Slave
Bus connector: 2 x RJ45
Max. baud rate: 10/100 Mbit/s
I/O Data: 480 Bytes IN/OUT
Protocol PROFIBUS
Master/Slave: Slave
Bus connector: D-SUB 9F
Max. baud rate: up to 12 Mbit/s
I/O Data: 244 Bytes IN/OUT
Protocol DeviceNet
Master/Slave: Slave
Bus connector: 5 pole / pitch 5.08
Max. baud rate: up to 500 Kbit/s
I/O Data: 512 Bytes IN/OUT
Protocol CANopen
Master/Slave: Slave
Bus connector: D-SUB 9M
Max. baud rate: up to 1 Mbit/s
I/O Data: 512 Bytes IN/OUT
Protocol Modbus RTU
Master/Slave: Slave
Bus connector: 8 pole / pitch 3.50
Max. baud rate: up to 115.2 Kbit/s
I/O Data: 512 Bytes IN/OUT
Protocol Serial
Master/Slave: Slave
Bus connector: 8 pole / pitch 3.50
Max. baud rate: up to 115.2 Kbit/s
I/O Data: 512 Bytes IN/OUT
Protocol DMX
Master/Slave: Master/Slave:
Bus connector: 8 pole / pitch 3.50
Max. baud rate: –
I/O Data: 512 Bytes IN/OUT
Real industrial suitability
Power supply: 12-24 VDC -15 % / +20 %
Operating temperature: -40 °C to 55 °C
ESD protection: 4 kV/8 kV according to EN 61131-2 and IEC 61000-6-2
Surge/Burst tests: applied according to EN 61131-2 and IEC 61000-6-2
EMI tests: according to EN 61131-2 and IEC 61000-6-2
UL certified (UL-File-No. E494534)